• BRL109 Quick View
    • BRL109 Quick View
    • BRL109

    • Relay base for SFXX0 optical sensor Relay base 12V NO / NC contacts used in safety installations with lock. • Power supply: 9-30 VDC • Cable section: 0.4-2mm • Humidity 95% / 25 ° C • Dimensions: diameter 100mm h = 12mm • Weight: 35g
    • Read more
  • FD9004L Quick View
  • FDB7130 Quick View
    • FDB7130 Quick View
    • FDB7130

    • Conventional reflective beam detector 5-100 m with reflector FDB7130 Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between the…
    • Read more
  • FDCP109 Quick View
  • FDCWS100AV Quick View
    • FDCWS100AV Quick View
    • FDCWS100AV

    • Sounder with flash en 54 3 and 23 Conventional wall siren with flashing light, modular and flexible design, easy to install, possibility of silencing the siren for use of the flashing light only, two-stage alarm capability
    • Read more
  • One Module111 Quick View
    • One Module111 Quick View
    • One Module111

    • Addresable Module 1 input 1 output form C 1 supervised output with short circuit isolator Using these devices it is possible to interface the loop with different systems, or to activate, by means of output modules, any type of output (sounders, light signals, fire doors electromagnets, etc.) Functional Features Reduced dimension permits device installation in any environment type. Devices are…
    • Read more
  • OneCallPoint Quick View
    • OneCallPoint Quick View
    • ,
    • OneCallPoint

    • Addresable Manual call point Activation is signaled with a red led and glass break effect, the call point can be reset with the provided key. Each call point is provided with integrated short circuit isolator that automatically takes action in case of need. The address can be programmed by means of the programmer or with the addressing function of Teledata…
    • Read more
  • OneDetector1 Quick View
    • OneDetector1 Quick View
    • OneDetector1

    • Dual Optical detector with short circuit isolator The OneDetector1 ensures an analysis of air condition and temperature of the protected area, and immunity to false alarms utilising the dual-path optical smoke detection technologies and algorithms for improved performance. The 360° visible LED with three different colours signals a condition of alarm (red), fault (yellow) and localization (green). Each detector is…
    • Read more
  • OneDetector2 Quick View
    • OneDetector2 Quick View
    • OneDetector2

    • Thermal and thermovelocimetric detector with short circuit isolator The OneDetector2 ensures the analysis of the air temperature of the protected area and immunity to false alarms. The 360° visible LED with three different colours signals a condition of alarm (red), fault (yellow) and localization (green). Each detector is provided with an integrated isolator circuit, that automatically takes action. The address…
    • Read more
  • OneKbd Quick View
    • OneKbd Quick View
    • OneKbd

    • Remote keyboard touch screen Functional Features Same as to the TeledataOne the OneKBD is easy and intuitive to use. All functions can be reached with a touch according to the different levels of access. It offers the possibility of events and historical display
    • Read more
  • OneMini Quick View
    • OneMini Quick View
    • OneMini

    • OneMini 1 loop panel with 240 devices per loop Networkable Lan Option Repeater option OneMini is the fire alarm control panel of the future completely made in Italy. Created from TeledataOne, the first fire alarm control panel with touch-screen technology, OneMini represent a compact and cost effective solution certified EN 54-2 and 4. The GUI interface is user friendly, you…
    • Read more
  • SF109 Quick View
    • SF109 Quick View
    • SF109

    • Conventional Smoke detector Technical Features • Certification : EN54 part 7 • High threshold of temperature for alarm 58°C Functional Features Low profile detector to match conventional analogue BSE109 base , made of plastic material and with a modern design.
    • Read more
  • SF309 Quick View
    • SF309 Quick View
    • SF309

    • Conventional rate of rise detector Functional Features Low profile detector to match conventional analogue BSE109 base , made of plastic material and with a modern design.
    • Read more
  • Sound100 Quick View
    • Sound100 Quick View
    • Sound100

    • Addressed siren EN 54 3 with short-circuit isolator Sound emission can be manually adjusted on the sounder itself. At the moment of activation, groups of sounders can be synchronized. Each sounder is provided with integrated isolator circuit, that automatically takes action in case of need. Addresses can be programmed by means of the programmer or with the addressing function of…
    • Read more
  • Sound101 Quick View
    • Sound101 Quick View
    • Sound101

    • Addressed siren EN 54 3 with flashing light and short-circuit isolator Sound emission can be manually adjusted on the sounder itself. At the moment of activation, groups of sounders can be synchronized. Each sounder is provided with integrated isolator circuit, that automatically takes action in case of need. Addresses can be programmed by means of the programmer or with the…
    • Read more